SPECIFICATIONS :
| Nominal Diameter(DN) |
15 mm |
| Connection for flange |
DN 15 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
165 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
10…600 l/h |
| Max. continuous flow |
400 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
1 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
15 mm |
| With threaded ends |
3/4” (for couplings 1/2”) |
| Nominal pressure |
PN 16 bar |
| Installation length |
165 mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
10…600 l/h |
| Max. continuous flow |
400 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
20 mm |
| Connection for flange |
DN 20 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
165 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
30…1500 l/h |
| Max. continuous flow |
1000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
20 mm |
| With threaded ends 1” |
(for couplings 3/4”) |
| Nominal pressure |
PN 16 bar |
| Installation length |
165 mm |
| Connection |
Drat |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
30…1500 l/h |
| Max. continuous flow |
1000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
25 mm |
| Connection for flange |
DN 25 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
190 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
75…3000 l/h |
| Max. continuous flow |
2000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
25 mm |
| With threaded ends |
1-1/4″ (for couplings 1″) |
| Nominal pressure |
PN 16 bar |
| Installation length |
190 mm |
| Connection |
Drat |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
75…3000 l/h |
| Max. continuous flow |
2000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
4 mm |
| Connection (bottom) |
G1/8″ inside thread |
| Nominal pressure |
PN 25 bar |
| Dimensions |
65 x 65 x 79 mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
60°C |
| Measuring range |
1…80 l/h |
| Max. continuous flow |
50 l/h |
| Max. measuring deviation |
2.0…80 l/h ± 1% |
| 1…2 l/h +1/-2 % |
| Repeatability |
± 0.2% |
| Registration capacity |
100000 Litres |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
4 mm |
| Connection (bottom) |
G1/8″ inside thread |
| Nominal pressure |
PN 25 bar |
| Dimensions |
65 x 65 x 79 mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
60°C |
| Measuring range |
1…80 l/h |
| Max. continuous flow |
50 l/h |
| Max. measuring deviation |
2.0…80 l/h ± 1% |
| 1…2 l/h +1/-2 % |
| Repeatability |
± 0.2% |
| Registration capacity |
100000 Litres |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
40 mm |
| Connection for flange |
DN 40 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
300 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
225…9000 l/h |
| Max. continuous flow |
6000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
40 mm |
| With threaded ends 2″ |
(for couplings 1-1/2″) |
| Nominal pressure |
PN 16 bar |
| Installation length |
300 mm |
| Connection |
Drat |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
225…9000 l/h |
| Max. continuous flow |
6000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
50 mm |
| Connection for flange |
DN 50 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
350 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
750…30000 l/h |
| Max. continuous flow |
20000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
1 Litres |
| Registration capacity |
100 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
8 mm |
| Connection (bottom) |
G1/4″ inside thread |
| Nominal pressure |
PN 25 bar |
| Dimensions |
65 x 65 x 79 mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
60°C |
| Measuring range |
4…200 l/h |
| Max. continuous flow |
135 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Registration capacity |
1000000 Litres |