SPECIFICATIONS :
Nominal Diameter(DN) |
15 mm |
Connection for flange |
DN 15 to DIN 2501 |
Nominal pressure |
PN 25 bar |
Installation length |
165 mm |
Connection |
Flange |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
10…600 l/h |
Max. continuous flow |
400 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
Registration capacity |
1 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
15 mm |
With threaded ends |
3/4” (for couplings 1/2”) |
Nominal pressure |
PN 16 bar |
Installation length |
165 mm |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
10…600 l/h |
Max. continuous flow |
400 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
20 mm |
Connection for flange |
DN 20 to DIN 2501 |
Nominal pressure |
PN 25 bar |
Installation length |
165 mm |
Connection |
Flange |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
30…1500 l/h |
Max. continuous flow |
1000 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
20 mm |
With threaded ends 1” |
(for couplings 3/4”) |
Nominal pressure |
PN 16 bar |
Installation length |
165 mm |
Connection |
Drat |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
30…1500 l/h |
Max. continuous flow |
1000 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
25 mm |
Connection for flange |
DN 25 to DIN 2501 |
Nominal pressure |
PN 25 bar |
Installation length |
190 mm |
Connection |
Flange |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
75…3000 l/h |
Max. continuous flow |
2000 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
25 mm |
With threaded ends |
1-1/4″ (for couplings 1″) |
Nominal pressure |
PN 16 bar |
Installation length |
190 mm |
Connection |
Drat |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
75…3000 l/h |
Max. continuous flow |
2000 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
4 mm |
Connection (bottom) |
G1/8″ inside thread |
Nominal pressure |
PN 25 bar |
Dimensions |
65 x 65 x 79 mm |
Installation position |
horizontal / vertical |
Temperature, max. |
60°C |
Measuring range |
1…80 l/h |
Max. continuous flow |
50 l/h |
Max. measuring deviation |
2.0…80 l/h ± 1% |
1…2 l/h +1/-2 % |
Repeatability |
± 0.2% |
Registration capacity |
100000 Litres |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
4 mm |
Connection (bottom) |
G1/8″ inside thread |
Nominal pressure |
PN 25 bar |
Dimensions |
65 x 65 x 79 mm |
Installation position |
horizontal / vertical |
Temperature, max. |
60°C |
Measuring range |
1…80 l/h |
Max. continuous flow |
50 l/h |
Max. measuring deviation |
2.0…80 l/h ± 1% |
1…2 l/h +1/-2 % |
Repeatability |
± 0.2% |
Registration capacity |
100000 Litres |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
40 mm |
Connection for flange |
DN 40 to DIN 2501 |
Nominal pressure |
PN 25 bar |
Installation length |
300 mm |
Connection |
Flange |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
225…9000 l/h |
Max. continuous flow |
6000 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
40 mm |
With threaded ends 2″ |
(for couplings 1-1/2″) |
Nominal pressure |
PN 16 bar |
Installation length |
300 mm |
Connection |
Drat |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
225…9000 l/h |
Max. continuous flow |
6000 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
0.01 Litres |
Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
50 mm |
Connection for flange |
DN 50 to DIN 2501 |
Nominal pressure |
PN 25 bar |
Installation length |
350 mm |
Connection |
Flange |
Installation position |
horizontal / vertical |
Temperature, max. |
130°C |
Measuring range |
750…30000 l/h |
Max. continuous flow |
20000 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Smallest readable value |
1 Litres |
Registration capacity |
100 Mio L |
-

SPECIFICATIONS :
Nominal Diameter(DN) |
8 mm |
Connection (bottom) |
G1/4″ inside thread |
Nominal pressure |
PN 25 bar |
Dimensions |
65 x 65 x 79 mm |
Installation position |
horizontal / vertical |
Temperature, max. |
60°C |
Measuring range |
4…200 l/h |
Max. continuous flow |
135 l/h |
Max. measuring deviation |
± 1% of measured value |
Repeatability |
± 0.2% |
Registration capacity |
1000000 Litres |