• ITRON WATER METER FLOSTAR-M DN100 (4 INCH)

     

    SPECIFICATIONS :
    Nominal Diameter(DN) : 100mm (4″)
    Type : Flostar M
    Minimal flowrate (Q1) : 250 L/h
    Transitional flowrate (Q2) : 400 L/h
    Permanent flowrate (Q3) : 100 m3/h
    Overload flowrate (Q4) : 125 m3/h
    Approval ratio (Q3/Q1) : 400
    Q2/Q1 : 1.6
    Accuracy class : 2
    Temperature class : T50 °C
    Pressure Class : 16
    Pressure loss Class : ∆P63
    Max. Admissible Pressure (MAP) : 16 Bar
    Verification scale interval : 0,2 L
    Indicating range : 999.999 m3
  • ITRON WATER METER FLOSTAR-M DN150 (6 INCH)

     

    SPECIFICATIONS :
    Nominal Diameter(DN) : 150mm (6″)
    Type : Flostar M
    Minimal flowrate (Q1) : 254 L/h
    Transitional flowrate (Q2) : 406 L/h
    Permanent flowrate (Q3) : 160 m3/h
    Overload flowrate (Q4) : 200 m3/h
    Approval ratio (Q3/Q1) : 630
    Q2/Q1 : 1.6
    Accuracy class : 2
    Temperature class : T30 °C
    Pressure Class : 16
    Pressure loss Class : ∆P63
    Max. Admissible Pressure (MAP) : 20 Bar
    Verification scale interval : 2 L
    Indicating range : 999.999.9 m3
  • ITRON WATER METER FLOSTAR-M DN40 (1-1/2 INCH)

     

    SPECIFICATIONS :
    Nominal Diameter(DN) : 40mm (1″-1/2)
    Type : Flostar M
    Minimal flowrate (Q1) : 80 L/h
    Transitional flowrate (Q2) : 160 L/h
    Permanent flowrate (Q3) : 16 m3/h
    Overload flowrate (Q4) : 20 m3/h
    Approval ratio (Q3/Q1) : 200
    Q2/Q1 : 1.6
    Accuracy class : 2
    Temperature class : T50 °C
    Pressure Class : 16
    Pressure loss Class : ∆P63
    Max. Admissible Pressure (MAP) : 16 Bar
    Verification scale interval : 0,2 L
    Indicating range : 999.999 m3
  • ITRON WATER METER FLOSTAR-M DN50 (2 INCH)

     

    SPECIFICATIONS :
    Nominal Diameter(DN) : 50mm (2″)
    Type : Flostar M
    Minimal flowrate (Q1) : 79 L/h
    Transitional flowrate (Q2) : 127 L/h
    Permanent flowrate (Q3) : 25 m3/h
    Overload flowrate (Q4) : 31,25 m3/h
    Approval ratio (Q3/Q1) : 315
    Q2/Q1 : 1.6
    Accuracy class : 2
    Temperature class : T50 °C
    Pressure Class : 16
    Pressure loss Class : ∆P63
    Max. Admissible Pressure (MAP) : 16 Bar
    Verification scale interval : 0,2 L
    Indicating range : 999.999 m3
  • ITRON WATER METER FLOSTAR-M DN65 (2-1/2 INCH)

     

    SPECIFICATIONS :
    Nominal Diameter(DN) : 65mm (2″ 1/2)
    Type : Flostar M
    Minimal flowrate (Q1) : 100 L/h
    Transitional flowrate (Q2) : 160 L/h
    Permanent flowrate (Q3) : 40 m3/h
    Overload flowrate (Q4) : 50 m3/h
    Approval ratio (Q3/Q1) : 400
    Q2/Q1 : 1.6
    Accuracy class : 2
    Temperature class : T50 °C
    Pressure Class : 16
    Pressure loss Class : ∆P63
    Max. Admissible Pressure (MAP) : 16 Bar
    Verification scale interval : 0,2 L
    Indicating range : 999.999 m3
  • ITRON WATER METER FLOSTAR-M DN80 (3 INCH)

     

    SPECIFICATIONS :
    Nominal Diameter(DN) : 80mm (3″)
    Type : Flostar M
    Minimal flowrate (Q1) : 157 L/h
    Transitional flowrate (Q2) : 252 L/h
    Permanent flowrate (Q3) : 63 m3/h
    Overload flowrate (Q4) : 78 m3/h
    Approval ratio (Q3/Q1) : 400
    Q2/Q1 : 1.6
    Accuracy class : 2
    Temperature class : T50 °C
    Pressure Class : 16
    Pressure loss Class : ∆P63
    Max. Admissible Pressure (MAP) : 16 Bar
    Verification scale interval : 0,2 L