• Vortex Flowmeter Delta Flowpet-DX

    OVAL FLOW METER DELTA FLOPET DX

     

    GENERAL SPECIFICATIONS
    Function With pressure compensation
    (Saturated steam, gas)
    Without pressure compensation
    (Liquid, gas, steam)
    Nominal size 15, 25, 40, 50, 80, 100, 150mm
    Connection Wafer type
    Connection standard JIS 10, 20, 30K ASME/JPI 150, 300
    Flow range Liquid (water) 0.8 to 645m3/h (7 types)/h(7形式)
    Gas (0.2 MPa air) 4.0 to 2780m3/h (7 types)
    Steam
    (0.5 MPa saturated steam)
    12.4 to 8820kg/h (7 types)
    Operating temp. range Maximum +200°C –30 to +200°C
    Max. operating pressure 1.0MPa 1.45MPa 5.0MPa 5.0MPa
    Accuracy ±2% of reading  ±1% of reading
    Power supply DC-powered
    Body material SCS14A
    Configuration Non-explosionproof configuration, IP65 or equivalent
    Output Pulse (flowrate), Analog (flowrate or pressure)

    ※:Accuracy at the pressure of 0.25 MPa or more. ±3% or RD in case of 0.06 to 0.25 MPa.

  • Oval Flowmeter Eggs Delta Pulse

    OVAL FLOW METER Eggs DELTA Pulse

     

    GENERAL SPECIFICATIONS
    Nominal size 4mm 8mm 15mm 25mm
    Flow range
    (L/min)
    Liquid 0.4 to 4 1.1 to 15 2.8 to 45 8.3 to 133
    Gas 7.2 to 17 18 to 90 55 to 283 167 to 850
    Connection RR male screw (plastic resin), Rc female screw (metal),
    NPT male screw (plastic resin)
    Applicable fluids Liquid (cooling water, pure water), gas (air, nitrogen)
    Body material PPS plastic resin
    Operating temp. range –10 to +80°C
    Max. operating pressure 0.98MPa
    Accuracy Liquids: ±2% of full scale Gas: ±3% of full scale
    Configuration Explosionproof or non-explosionproof, IP65
    Power supply DC-powered
    Output Pulse
  • Oval Flowmeter Eggs DELTAⅡ

    OVAL FLOW METER Eggs DELTAⅡ

     

    GENERAL SPECIFICATIONS
    Nominal size 4mm 8mm 15mm 25mm
    Flow range
    (L/min)
    Liquid 0.4 to 4 1.1 to 15 2.8 to 45 8.3 to 133
    Gas 7.2 to 17 18 to 90 55 to 283 167 to 850
    Connection R male screw (plastic resin), Rc female screw (metal),
    NPT male screw (plastic resin)
    Applicable fluids Liquid (cooling water, pure water), gas (air, nitrogen)
    Body material PPS plastic resin
    Operating temp. range -10 to +80℃
    Max. operating pressure 0.98MPa
    Accuracy Liquids: ±2% of full scale Gas: ±3% of full scale
    Configuration Non-explosionproof, IP53 equivalent
    Power supply DC-powered or battery-powered
    Output Analog, pulse (flowrate, alarm)
  • Oval Flow Meter Vortex EX Delta II Battery Powered PAF5

    OVAL FLOW METER VORTEX EX DELTA II Battery Powered PAF5 Model

     

    GENERAL SPECIFICATIONS
    Model Standard Dia-shaped
    Nominal
    size
    Wafer type 10 to 150mm(15 mm min. for steam) 15 to 80mm
    Flange type 15 to 300mm 50, 80mm
    Applicable tube size
    Flow
    range
    Fluid (water) 0.2* to 2510m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    0.8 to 172m3/h(5 types)
    Gas (0.2 MPa air) 2*to 15000m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    Steam (0.5 MPa
    saturated steam)
    0.02 to 47.6t/h (10 types)
    (15mm min.)
    Applicable fluid Liquid, gas, steam Liquid
    Operating temp. range –30 to +300°C
    –30 to +460°C(For high temperature of replaceable sensor)
    Flange standard JIS 10, 20, 30K ASME/JPI 150, 300, 600
    Max. operating pressure 4.51MPa (Depends on flange standard and flange material.)
    Accuracy ±1% of reading or ±1% of full scale
    Power supply DC-powered or battery-powered
    Body material SUS316 or SCS14A
    Configuration Explosionproof or non-explosionproof,
    IP66 (DC-powered), IP65 (battery-powered))
    Output Analog, pulse
  • Oval Flow Meter Vortex EX Delta II Smart Model

    OVAL FLOW METER VORTEX EX DELTA II SMART MODEL

     

    GENERAL SPECIFICATIONS
    Model Standard Dia-shaped
    Nominal
    size
    Wafer type 10 to 150mm(15 mm min. for steam) 15 to 80mm
    Flange type 15 to 300mm 50, 80mm
    Applicable tube size
    Flow
    range
    Fluid (water) 0.2* to 2510m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    0.8 to 172m3/h(5 types)
    Gas (0.2 MPa air) 2*to 15000m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    Steam (0.5 MPa
    saturated steam)
    0.02 to 47.6t/h (10 types)
    (15mm min.)
    Applicable fluid Liquid, gas, steam Liquid
    Operating temp. range –30 to +300°C
    –30 to +460°C(For high temperature of replaceable sensor)
    Flange standard JIS 10, 20, 30K ASME/JPI 150, 300, 600
    Max. operating pressure 4.51MPa (Depends on flange standard and flange material.)
    Accuracy ±1% of reading or ±1% of full scale
    Power supply DC-powered or battery-powered
    Body material SUS316 or SCS14A
    Configuration Explosionproof or non-explosionproof,
    IP66 (DC-powered), IP65 (battery-powered))
    Output Analog, pulse