SPECIFICATIONS :
| Model |
: Amico LXSG-80E |
| Nominal Diameter |
: 80 mm (3 Inch) |
| Maximum Flow Rate (Q max.) |
: 80 m³/h |
| Nominal FLow Rate (Qn) |
: 63 m³/h |
| Transitional Flow Rate (Qt) |
: 8 m³/h |
| Minimum Flow Rate (Qmin) |
: 1.3 m³/h |
| Accuracy within (Q max-Q min) |
: ±2% (Qmax-Qt) |
|
: ±5% (Qt-Qmin) |
| Working pressure |
: 10 Bar |
| Starting Flow Rate |
: 0.020 m³/h |
| Max reading |
: 9999999.99 m³ |
| Min reading |
: 0.01 m³ |
-

Specifications :
| Nominal Diameter(DN) |
15mm |
| Connection for flanges |
DN 15 to DIN 2501 |
| Nominal pressure |
PN25 bar |
| Installation length |
165mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
20…600 l/h |
| Max. continuous flow |
400 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Registration capacity |
100 Mio L |
-

Specifications :
| Nominal Diameter(DN) |
15mm |
| Threaded connection 3/4″ |
Couplings for pipe 1/2” |
| Nominal pressure |
PN16 bar |
| Installation length |
165mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
20…600 l/h |
| Max. continuous flow |
400 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Registration capacity |
100 Mio L |
-

Specifications :
| Nominal Diameter(DN) |
20mm |
| Connection for flanges |
DN 20 to DIN 2501 |
| Nominal pressure |
PN16 bar |
| Installation length |
165mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
40…1500 l/h |
| Max. continuous flow |
1000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Approx. starting flow rate |
12 l/h |
-

Specifications :
| Nominal Diameter(DN) |
20mm |
| Min Flow rate |
40 l/h |
| Nominal pressure |
PN16 bar |
| Installation length |
165mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
1500 l/h |
| Max. continuous flow |
1000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Approx. starting flow rate |
12 l/h |
-

Specifications :
| Nominal Diameter(DN) |
25mm |
| Connection for flanges |
DN 25 to DIN 2501 |
| Nominal pressure |
PN25 bar |
| Installation length |
190mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
75…3000 l/h |
| Max. continuous flow |
2000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Approx. starting flow rate |
30 l/h |
-

Specifications :
| Nominal Diameter(DN) |
25mm |
| Min Flow rate |
75 l/h |
| Nominal pressure |
PN16 bar |
| Installation length |
190mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
3000 l/h |
| Max. continuous flow |
2000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Approx. starting flow rate |
30 l/h |
-


Specifications :
| Nominal Diameter(DN) |
40mm |
| Nominal pressure RC |
PN16 bar |
| Nominal pressure FL |
PN25 bar |
| Installation length |
300mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Range flow rate |
225…9000 l/h |
| Max. continuous flow |
6000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Approx. starting flow rate |
90 l/h |
-

Specifications :
| Nominal Diameter(DN) |
50mm |
| Nominal pressure RC |
PN16 bar |
| Nominal pressure FL |
PN25 bar |
| Installation length |
350mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Range flow rate |
750…30000 l/h |
| Max. continuous flow |
20000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Analog |
4…20mA |
| Approx. starting flow rate |
300 l/h |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
15 mm |
| Connection for flange |
DN 15 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
165 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
10…600 l/h |
| Max. continuous flow |
400 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
1 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
15 mm |
| With threaded ends |
3/4” (for couplings 1/2”) |
| Nominal pressure |
PN 16 bar |
| Installation length |
165 mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
10…600 l/h |
| Max. continuous flow |
400 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
20 mm |
| Connection for flange |
DN 20 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
165 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
30…1500 l/h |
| Max. continuous flow |
1000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
20 mm |
| With threaded ends 1” |
(for couplings 3/4”) |
| Nominal pressure |
PN 16 bar |
| Installation length |
165 mm |
| Connection |
Drat |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
30…1500 l/h |
| Max. continuous flow |
1000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
25 mm |
| Connection for flange |
DN 25 to DIN 2501 |
| Nominal pressure |
PN 25 bar |
| Installation length |
190 mm |
| Connection |
Flange |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
75…3000 l/h |
| Max. continuous flow |
2000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
25 mm |
| With threaded ends |
1-1/4″ (for couplings 1″) |
| Nominal pressure |
PN 16 bar |
| Installation length |
190 mm |
| Connection |
Drat |
| Installation position |
horizontal / vertical |
| Temperature, max. |
130°C |
| Measuring range |
75…3000 l/h |
| Max. continuous flow |
2000 l/h |
| Max. measuring deviation |
± 1% of measured value |
| Repeatability |
± 0.2% |
| Smallest readable value |
0.01 Litres |
| Registration capacity |
10 Mio L |
-

SPECIFICATIONS :
| Nominal Diameter(DN) |
4 mm |
| Connection (bottom) |
G1/8″ inside thread |
| Nominal pressure |
PN 25 bar |
| Dimensions |
65 x 65 x 79 mm |
| Installation position |
horizontal / vertical |
| Temperature, max. |
60°C |
| Measuring range |
1…80 l/h |
| Max. continuous flow |
50 l/h |
| Max. measuring deviation |
2.0…80 l/h ± 1% |
| 1…2 l/h +1/-2 % |
| Repeatability |
± 0.2% |
| Registration capacity |
100000 Litres |