Specifications :
Performance data WS-Dynamic 130 ºC For Hot Water
Nominal Diameter(DN) |
: 100mm (4″) |
Max. peak flow (Qmax) |
: 125 m3/h |
Continuous flow (Qn) |
: 60 m3/h |
Transitional flow (Qt) |
: 4.0 m3/h |
Min. flow (Qmin) |
: 0.50 m3/h |
Starting flow |
: 0.15 m3/h |
Performance data table according to PTB-A22 specification class C
Nominal Diameter(DN) |
: 100mm (4″) |
Max. peak flow (Qmax) |
: 120 m3/h |
Continuous flow (Qn) |
: 60 m3/h |
Transitional flow (Qt) |
: 6.0 m3/h |
Min. flow (Qmin) |
: 4.8 m3/h |
-

Specifications :
Performance data WS-Dynamic 130 ºC For Hot Water
Nominal Diameter(DN) |
: 150mm (6″) |
Max. peak flow (Qmax) |
: 300 m3/h |
Continuous flow (Qn) |
: 150 m3/h |
Transitional flow (Qt) |
: 12 m3/h |
Min. flow (Qmin) |
: 0.80 m3/h |
Starting flow |
: 0.50 m3/h |
Performance data table according to PTB-A22 specification class C
Nominal Diameter(DN) |
: 150mm (6″) |
Max. peak flow (Qmax) |
: 300 m3/h |
Continuous flow (Qn) |
: 150 m3/h |
Transitional flow (Qt) |
: 15.0 m3/h |
Min. flow (Qmin) |
: 12.0 m3/h |
-

Specifications :
Performance data WS-Dynamic 130 ºC For Hot Water
Nominal Diameter(DN) |
: 50mm (2″) |
Max. peak flow (Qmax) |
: 30 m3/h |
Continuous flow (Qn) |
: 15 m3/h |
Transitional flow (Qt) |
: 1.5 m3/h |
Min. flow (Qmin) |
: 0.25 m3/h |
Starting flow |
: 0.06 m3/h |
Performance data table according to PTB-A22 specification class C
Nominal Diameter(DN) |
: 50mm (2″) |
Max. peak flow (Qmax) |
: 30 m3/h |
Continuous flow (Qn) |
: 15 m3/h |
Transitional flow (Qt) |
: 1.5 m3/h |
Min. flow (Qmin) |
: 1.2 m3/h |
-

Specifications :
Performance data WS-Dynamic 130 ºC For Hot Water
Nominal Diameter(DN) |
: 65mm (2″-1/2) |
Max. peak flow (Qmax) |
: 60 m3/h |
Continuous flow (Qn) |
: 25 m3/h |
Transitional flow (Qt) |
: 2.5 m3/h |
Min. flow (Qmin) |
: 0.30 m3/h |
Starting flow |
: 0.07 m3/h |
Performance data table according to PTB-A22 specification class C
Nominal Diameter(DN) |
: 65mm (2″-1/2) |
Max. peak flow (Qmax) |
: 50 m3/h |
Continuous flow (Qn) |
: 25 m3/h |
Transitional flow (Qt) |
: 2.5 m3/h |
Min. flow (Qmin) |
: 2.0 m3/h |
-

Specifications :
Performance data WS-Dynamic 130 ºC For Hot Water
Nominal Diameter(DN) |
: 80mm (3″) |
Max. peak flow (Qmax) |
: 85 m3/h |
Continuous flow (Qn) |
: 40 m3/h |
Transitional flow (Qt) |
: 2.5 m3/h |
Min. flow (Qmin) |
: 0.30 m3/h |
Starting flow |
: 0.10 m3/h |
Performance data table according to PTB-A22 specification class C
Nominal Diameter(DN) |
: 80mm (3″) |
Max. peak flow (Qmax) |
: 80 m3/h |
Continuous flow (Qn) |
: 40 m3/h |
Transitional flow (Qt) |
: 4.0 m3/h |
Min. flow (Qmin) |
: 3.2 m3/h |