GENERAL SPECIFICATIONS
| Model |
CA00A, CA001, CA003, CA006, CA010, CA015, CA025, CA040, CA050, CA080, CA100, CA150, CA15H, CA200, CA20H, CA250 |
| Nominal size |
1/4”, 10mm, 15mm, 25mm, 40mm, 50mm, 80mm, 100mm, 150mm, 200mm, 250mm |
| Process Connection |
JIS 10, 20, 30, 40, 63K RF
ASME 150, 300, 600 RF, JPI 150, 300, 600 RF
DIN PN 10, 16, 25, 40RF, Ferrule, Screw |
| Acceptable fluids |
Liquids, Gases |
| Flow range |
0 to 2800000kg/h (16 models) |
| Accuracy |
Flowrate |
Liquids |
±0.1%RD (CA003 to CA200)
±0.1%RD±Zero stability error (CA20H to CA250, High temperature service model)
±0.2%RD (CA00A, CA001)
±0.2%RD±Zero stability error (High pressure service model) |
| Gases |
±0.5%RD±Zero stability error |
| Density |
Liquids |
±0.0005g/mL (CA003 to CA250)
±0.003g/mL (CA00A, CA001, High temperature service model)
±0.004g/mL (High pressure service model) |
Temperature range
(Differs by explosionproof
specification) |
Standard model : −200 to +200℃ (Applicable to all models) |
| High temperature service model : −40 to +350℃ (CA025 to CA150) |
| Low temperature service model : −200 to +50℃ (CA025 to CA250) (Explosionproof model) |
| Max. operating pressure |
Depends on flange rating |
| Wetted materials |
SUS 316L, SUS 316L+Alloy C, Alloy CC |
| Explosionproof specification |
TIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI |
| Maritime certification |
DNV GL |
-

GENERAL SPECIFICATIONS
| Function |
With pressure compensation
(Saturated steam, gas) |
Without pressure compensation
(Liquid, gas, steam) |
| Nominal size |
15, 25, 40, 50, 80, 100, 150mm |
| Connection |
Wafer type |
| Connection standard |
|
JIS 10, 20, 30K ASME/JPI 150, 300 |
| Flow range |
Liquid (water) |
– |
0.8 to 645m3/h (7 types)/h(7形式) |
| Gas (0.2 MPa air) |
4.0 to 2780m3/h (7 types) |
Steam
(0.5 MPa saturated steam) |
12.4 to 8820kg/h (7 types) |
| Operating temp. range |
Maximum +200°C |
–30 to +200°C |
| Max. operating pressure |
1.0MPa |
1.45MPa |
5.0MPa |
5.0MPa |
| Accuracy |
±2% of reading |
±1% of reading |
| Power supply |
DC-powered |
| Body material |
SCS14A |
| Configuration |
Non-explosionproof configuration, IP65 or equivalent |
| Output |
Pulse (flowrate), Analog (flowrate or pressure) |
-

GENERAL SPECIFICATIONS
| Nominal size |
4mm |
8mm |
15mm |
25mm |
Flow range
(L/min) |
Liquid |
0.4 to 4 |
1.1 to 15 |
2.8 to 45 |
8.3 to 133 |
| Gas |
7.2 to 17 |
18 to 90 |
55 to 283 |
167 to 850 |
| Connection |
RR male screw (plastic resin), Rc female screw (metal),
NPT male screw (plastic resin) |
| Applicable fluids |
Liquid (cooling water, pure water), gas (air, nitrogen) |
| Body material |
PPS plastic resin |
| Operating temp. range |
–10 to +80°C |
| Max. operating pressure |
0.98MPa |
| Accuracy |
Liquids: ±2% of full scale Gas: ±3% of full scale |
| Configuration |
Explosionproof or non-explosionproof, IP65 |
| Power supply |
DC-powered |
| Output |
Pulse |
-

GENERAL SPECIFICATIONS
| Nominal size |
4mm |
8mm |
15mm |
25mm |
Flow range
(L/min) |
Liquid |
0.4 to 4 |
1.1 to 15 |
2.8 to 45 |
8.3 to 133 |
| Gas |
7.2 to 17 |
18 to 90 |
55 to 283 |
167 to 850 |
| Connection |
R male screw (plastic resin), Rc female screw (metal),
NPT male screw (plastic resin) |
| Applicable fluids |
Liquid (cooling water, pure water), gas (air, nitrogen) |
| Body material |
PPS plastic resin |
| Operating temp. range |
-10 to +80℃ |
| Max. operating pressure |
0.98MPa |
| Accuracy |
Liquids: ±2% of full scale Gas: ±3% of full scale |
| Configuration |
Non-explosionproof, IP53 equivalent |
| Power supply |
DC-powered or battery-powered |
| Output |
Analog, pulse (flowrate, alarm) |
-


GENERAL SPECIFICATIONS
| Model |
For oil |
For water |
| Standard |
For high temperature |
| Nominal size |
20、25、40、50mm |
20、25、40mm |
20、25、40、50mm |
| Connection |
JIS 10K Flange, ASME 150 Flange |
JIS 10K Flange |
| Flow range |
7 to 24000L/h (6 types) |
14 to 6400L/h (4 types) |
200 to 12000L/h (4 types) |
| Operating temp. range |
0 to 120°C |
0 to 150°C |
0 to 120 °C |
| Max. operating pressure |
1.18MPa |
0.98MPa |
1.18MPa(Still and flowing water) |
| Accuracy |
Within ±0.5% of reading |
Within ±1% of reading |
| Power supply |
DC-powered or battery-powered |
| Output |
Analog, Pulse |
| Configuration |
Non-explosionproof, IP65 (Install under the eaves) |
| Body material |
FC250 |
Stainless steel |
| Applicable fluids |
Kerosene oil, light oil, heavy oil |
water |
-

Major Specifications
| Model |
Single case type |
Double case (inner and outer cases) type |
| Nominal size |
80 to 200mm |
250 to 300mm |
25mm |
40, 50mm |
50 to 200mm |
| Transmission system |
7 |
4 |
2 |
4 |
| Connection standard (Flange) |
JIS 10,20K |
JIS 10,16,20,30K |
JIS 30K |
JIS 10,16,20,30,40,63K |
| ASME/JPI 150 |
ASME/JPI 150,300 |
ASME 300 |
ASME/JPI 150,300,600 |
| Flow range |
4 to 450m3/h
(5types) |
30 to 1000m3/h
(2types) |
0.08 to 4m3/h
(2types) |
0.26 to 40m3/h
(3types) |
2 to 450m3/h
(6types) |
| Operating temp. range |
-10 to +120°C |
-5 to +120°C |
-5 to +120°C
or
+120 to +200°C |
-5 to +120°C |
| Max. operating pressure |
1.96MPa
(Depends on connection standard.) |
4.59MPa
(Depends on connection standard.) |
4.51MPa
(120°C Max.) |
9.51MPa
(Depends on connection standard.) |
| Accuracy |
Within ±0.5% or ±0.2% of reading |
| Power supply |
Not necessary (Power supply is required for output available model.) |
| Output |
Pulse (Option) |
| Configuration |
Explosionproof and also output type is available. |
| Applicable fluids |
Water, gasoline, light oil, heavy oil, etc. |
Major Specifications (With jacket)
| Model |
Jacketed single case type |
| Nominal size |
25,40,50mm |
100,150,200mm |
| Transmission system |
7 |
| Connection standard (Flange) |
JIS 10K, ASME 150 |
| Flow range |
0.15 to 38m3/h
(5types) |
30 to 1000m3/h
(2types) |
| Operating temp. range |
-5 to +120°C or +120 to +200°C |
| Max. operating pressure |
1.18MPa (220°C Max.) |
| Accuracy |
Within ±0.5% of reading |
| Power supply |
Not necessary (Power supply is required for output furnished model.) |
| Output |
Pulse (Option) |
| Configuration |
Explosionproof and also output type is available. |
| Applicable fluids |
Water, gasoline, light oil, heavy oil, etc. |
-


GENERAL SPECIFICATIONS
| Model |
Standard |
Dia-shaped |
Nominal
size |
Wafer type |
10 to 150mm(15 mm min. for steam) |
15 to 80mm |
| Flange type |
15 to 300mm |
50, 80mm |
| Applicable tube size |
- |
- |
Flow
range |
Fluid (water) |
0.2 to 2510m3/h(11 types)
(* Accuracy ±2% FS at 10 mm) |
0.8 to 172m3/h(5 types) |
| Gas (0.2 MPa air) |
2to 15000m3/h(11 types)
(* Accuracy ±2% FS at 10 mm) |
- |
Steam (0.5 MPa
saturated steam) |
0.02 to 47.6t/h (10 types)
(15mm min.) |
- |
| Applicable fluid |
Liquid, gas, steam |
Liquid |
| Operating temp. range |
–30 to +300°C
–30 to +460°C(For high temperature of replaceable sensor) |
| Flange standard |
JIS 10, 20, 30K ASME/JPI 150, 300, 600 |
| Max. operating pressure |
4.51MPa (Depends on flange standard and flange material.) |
| Accuracy |
±1% of reading or ±1% of full scale |
| Power supply |
DC-powered or battery-powered |
| Body material |
SUS316 or SCS14A |
| Configuration |
Explosionproof or non-explosionproof,
IP66 (DC-powered), IP65 (battery-powered)) |
| Output |
Analog, pulse |
-

GENERAL SPECIFICATIONS
| Model |
Standard |
Dia-shaped |
Nominal
size |
Wafer type |
10 to 150mm(15 mm min. for steam) |
15 to 80mm |
| Flange type |
15 to 300mm |
50, 80mm |
| Applicable tube size |
- |
- |
Flow
range |
Fluid (water) |
0.2 to 2510m3/h(11 types)
(* Accuracy ±2% FS at 10 mm) |
0.8 to 172m3/h(5 types) |
| Gas (0.2 MPa air) |
2to 15000m3/h(11 types)
(* Accuracy ±2% FS at 10 mm) |
- |
Steam (0.5 MPa
saturated steam) |
0.02 to 47.6t/h (10 types)
(15mm min.) |
- |
| Applicable fluid |
Liquid, gas, steam |
Liquid |
| Operating temp. range |
–30 to +300°C
–30 to +460°C(For high temperature of replaceable sensor) |
| Flange standard |
JIS 10, 20, 30K ASME/JPI 150, 300, 600 |
| Max. operating pressure |
4.51MPa (Depends on flange standard and flange material.) |
| Accuracy |
±1% of reading or ±1% of full scale |
| Power supply |
DC-powered or battery-powered |
| Body material |
SUS316 or SCS14A |
| Configuration |
Explosionproof or non-explosionproof,
IP66 (DC-powered), IP65 (battery-powered)) |
| Output |
Analog, pulse |
-

Major specifications
| Model |
Standard type, low viscosity type |
Standard type, high viscosity type |
| Nominal size |
15~50mm |
80~400mm |
| Connection |
JIS 10, 16, 20, 30K Flange, ASME/JPI 150, 300 Flange |
| Flow range |
0.63~54m3/h(standard type, 5 types) |
10~4500m3/h(standard type, 8 types) |
| Operating temp. range |
-30~+120℃(standard, for non-explosionproof type) |
| Operating temp. range |
4.51 MPa (depends on connection standard and operating temperature) |
| Accuracy |
±0.2% or ±0.5% of reading |
| Power supply |
DC-powered |
| Body material |
SUS304, other |
| Output |
Analog or pulse |
| Configuration |
Explosionproof or non-explosionproof, IP66 |
| Applicable fluids |
Petroleum, liquefied gas, water, other |
-


Major specifications
| Model |
For cold water |
For hot water |
| Nominal Diameter |
40 to 300mm (10 types) |
40 to 300mm (10 types) |
| Connection |
JIS 10K Flange, ASME 150 Flange |
| Flow range |
0.7 to 2000m3/h (10 types) |
1.8 to 1200m3/h (10 types) |
| Operating temp. range |
0 to 50°C |
0 to 130°C |
| Max. operating pressure |
1MPa |
| Accuracy |
±2% or ±5% of reading |
| Power supply |
Not necessary (Power supply is required for output available model) |
| Body material |
SUS304, other |
| Output |
Pulse |
| Configuration |
Output available model is non-explosionproof type only |
| Applicable fluids |
Water |
-


GENERAL SPECIFICATIONS MINI METER
| Model |
Mini Meter (with built-in instrumental error adjuster) |
| Connection |
JIS 5K Flange |
ASME 150 Flange |
| Flow range |
Light oil: 20 to 800 L/h, Heavy oil: 10 to 800 L/h |
| Max. operating temp. |
100°C |
| Max. operating pressure |
0.69MPa |
1.04MPa |
| Accuracy |
Within ±0.5% of reading |
| Power supply |
Not necessary |
| Body material |
FC250, FCD450 |
| Output |
None (with dedicated indicator) |
| Configuration |
Non-explosionproof |
| Applicable fluids |
Light oil, heavy oil, etc. |
-


Major specifications
| Model |
Mechanical Counter |
| Nominal size |
80,100mm |
100 to 450mm |
Connection
standard
(Flange) |
JIS 10K |
JIS 20K |
ASME 125,
ASME/JPI 150 |
ASME/JPI 150 |
| Flow range |
8 to 180m3/h
(2types) |
17 to 2800m3/h
(7types) |
Operating
temp. range |
–5 to +120°C
or 0 to +120°C |
–5 to +120°C |
Max.
operating
pressure |
0.98MPa |
1.96MPa
(Depends on
connection standard) |
| Accuracy |
Within ±0.2%
of reading |
Within ±0.5% or
±0.2% of reading |
| Power supply |
Not necessary (Power supply is required
for output available model.) |
| Output |
Pulse (Option) |
| Configuration |
Explosionproof and also output type is available. |
| Body material |
FC250 or SCPH2 |
Applicable
fluids |
Water, gasoline, light oil, heavy oil, etc. |
-


Major specifications
| Model |
Electronic Counter (Ultra Counter) |
| Nominal size |
80 to 100mm |
100 to 450mm |
Connection
standard
(Flange) |
JIS 10K |
JIS 20K |
| ASME 125, ASME/JPI 150 |
ASME/JPI 150 |
| Flow range |
8 to 180m3/h (2types) |
17 to 2800m3/h (7types) |
| Operating temp. range |
–5 to +120°C or 0 to +120°C |
–5 to +120°C |
Max. operating
pressure |
1.37MPa (Depends on body material) |
1.96MPa (Depends on connection standard) |
| Accuracy |
Within ±0.2% of reading |
Within ±0.5% or ±0.2% of reading |
| Power supply |
DC-powered or battery-powered |
| Output |
Analog, pulse |
| Configuration |
Explosionproof or non-explosionproof, IP66 |
| Body material |
FC250 or SCPH2 |
| Applicable fluids |
Water, gasoline, light oil, heavy oil, etc.他 |
-

Major specifications
| Applicable fluids |
Oil, heavy oil, other liquids (Homogeneous liquid through which an ultrasonic wave propagates) |
| Nominal size |
100, 150, 200, 250, 300mm |
| Number of lines measured |
4 |
| Flange standard |
JIS 10, 20, 30K RF / JPI 150, 300 RF / ASME 150, 300 RF |
| Flow velocity measuring range |
−10 to +10m/s |
| Accuracy |
±0.5%RD (Standard), ±0.15%RD (high accuracy calibration) |
| Temp. range |
−20 to +120°C |
| Max. operating pressure |
Depends on flange rating (Design pressure : 8MPa at 120°C) |
| Configuration |
Explosionproof (TIIS, ATEX), IP66 |
-

Major specifications
| Applicable fluids |
Homogeneous fluids where ultrasonic wave can propagate (clean water, waste water, industrial water, river water, ocean water, purified water, etc.)
Turbidity: 10000mg/L (degree) max. |
| Fluid temp. range |
-20 to 60°C (fluid and ambient) |
| Nominal size |
25mm to 600mm |
| Piping materials |
Steel pipe, SUS pipe, polyvinyl pipe, ductile cast-iron pipe, copper pipe, or other pipe made of material that can transmit ultrasonic wave steadily |
| Flow metering range |
0 to ±10m/s |
| Number of metering lines |
1 line |
| Metering system |
Ultrasonic pulse transmission time difference system |
| Factory calibration accuracy |
25mm to 40mm |
±2.5% of reading (±0.025m/s at a flowrate less than 1m/s) |
| 50mm to 90mm |
±2.0% of reading (±0.020m/s at a flowrate less than 1m/s) |
| 100mm to 250mm |
±1.5% of reading (±0.015m/s at a flowrate less than 1m/s) |
| 300mm to 600mm |
±1.0% of reading (±0.010m/s at a flowrate less than 1m/s) |
-


Specifications :