• Flowmeter Coriolis ALTIMASS Type-U | Oval Flow Meters

    OVAL FLOW METER CORIOLIS ALTIMASS TYPE-U

     

    GENERAL SPECIFICATIONS
    Model CA00A, CA001, CA003, CA006, CA010, CA015, CA025, CA040, CA050, CA080, CA100, CA150, CA15H, CA200, CA20H, CA250
    Nominal size 1/4”, 10mm, 15mm, 25mm, 40mm, 50mm, 80mm, 100mm, 150mm, 200mm, 250mm
    Process Connection JIS 10, 20, 30, 40, 63K RF
    ASME 150, 300, 600 RF, JPI 150, 300, 600 RF
    DIN PN 10, 16, 25, 40RF, Ferrule, Screw
    Acceptable fluids Liquids, Gases
    Flow range 0 to 2800000kg/h (16 models)
    Accuracy Flowrate Liquids ±0.1%RD (CA003 to CA200)
    ±0.1%RD±Zero stability error (CA20H to CA250, High temperature service model)
    ±0.2%RD (CA00A, CA001)
    ±0.2%RD±Zero stability error (High pressure service model)
    Gases ±0.5%RD±Zero stability error
    Density Liquids ±0.0005g/mL (CA003 to CA250)
    ±0.003g/mL (CA00A, CA001, High temperature service model)
    ±0.004g/mL (High pressure service model)
    Temperature range
    (Differs by explosionproof
    specification)
    Standard model : −200 to +200℃ (Applicable to all models)
    High temperature service model : −40 to +350℃ (CA025 to CA150)
    Low temperature service model : −200 to +50℃ (CA025 to CA250) (Explosionproof model)
    Max. operating pressure Depends on flange rating
    Wetted materials SUS 316L, SUS 316L+Alloy C, Alloy CC
    Explosionproof specification TIIS, ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI
    Maritime certification DNV GL
  • Vortex Flowmeter Delta Flowpet-DX

    OVAL FLOW METER DELTA FLOPET DX

     

    GENERAL SPECIFICATIONS
    Function With pressure compensation
    (Saturated steam, gas)
    Without pressure compensation
    (Liquid, gas, steam)
    Nominal size 15, 25, 40, 50, 80, 100, 150mm
    Connection Wafer type
    Connection standard JIS 10, 20, 30K ASME/JPI 150, 300
    Flow range Liquid (water) 0.8 to 645m3/h (7 types)/h(7形式)
    Gas (0.2 MPa air) 4.0 to 2780m3/h (7 types)
    Steam
    (0.5 MPa saturated steam)
    12.4 to 8820kg/h (7 types)
    Operating temp. range Maximum +200°C –30 to +200°C
    Max. operating pressure 1.0MPa 1.45MPa 5.0MPa 5.0MPa
    Accuracy ±2% of reading  ±1% of reading
    Power supply DC-powered
    Body material SCS14A
    Configuration Non-explosionproof configuration, IP65 or equivalent
    Output Pulse (flowrate), Analog (flowrate or pressure)

    ※:Accuracy at the pressure of 0.25 MPa or more. ±3% or RD in case of 0.06 to 0.25 MPa.

  • Oval Flowmeter Eggs Delta Pulse

    OVAL FLOW METER Eggs DELTA Pulse

     

    GENERAL SPECIFICATIONS
    Nominal size 4mm 8mm 15mm 25mm
    Flow range
    (L/min)
    Liquid 0.4 to 4 1.1 to 15 2.8 to 45 8.3 to 133
    Gas 7.2 to 17 18 to 90 55 to 283 167 to 850
    Connection RR male screw (plastic resin), Rc female screw (metal),
    NPT male screw (plastic resin)
    Applicable fluids Liquid (cooling water, pure water), gas (air, nitrogen)
    Body material PPS plastic resin
    Operating temp. range –10 to +80°C
    Max. operating pressure 0.98MPa
    Accuracy Liquids: ±2% of full scale Gas: ±3% of full scale
    Configuration Explosionproof or non-explosionproof, IP65
    Power supply DC-powered
    Output Pulse
  • Oval Flowmeter Eggs DELTAⅡ

    OVAL FLOW METER Eggs DELTAⅡ

     

    GENERAL SPECIFICATIONS
    Nominal size 4mm 8mm 15mm 25mm
    Flow range
    (L/min)
    Liquid 0.4 to 4 1.1 to 15 2.8 to 45 8.3 to 133
    Gas 7.2 to 17 18 to 90 55 to 283 167 to 850
    Connection R male screw (plastic resin), Rc female screw (metal),
    NPT male screw (plastic resin)
    Applicable fluids Liquid (cooling water, pure water), gas (air, nitrogen)
    Body material PPS plastic resin
    Operating temp. range -10 to +80℃
    Max. operating pressure 0.98MPa
    Accuracy Liquids: ±2% of full scale Gas: ±3% of full scale
    Configuration Non-explosionproof, IP53 equivalent
    Power supply DC-powered or battery-powered
    Output Analog, pulse (flowrate, alarm)
  • Oval Flowmeter Flowpet-5g

    OVAL FLOW METER FLOWPET 5G

     

    GENERAL SPECIFICATIONS
    Model For oil For water
    Standard For high temperature
    Nominal size 20、25、40、50mm 20、25、40mm 20、25、40、50mm
    Connection JIS 10K Flange, ASME 150 Flange JIS 10K Flange
    Flow range* 7 to 24000L/h (6 types)* 14 to 6400L/h (4 types)* 200 to 12000L/h (4 types)
    Operating temp. range 0 to 120°C 0 to 150°C 0 to 120 °C
    Max. operating pressure 1.18MPa 0.98MPa 1.18MPa(Still and flowing water)
    Accuracy Within ±0.5% of reading Within ±1% of reading
    Power supply DC-powered or battery-powered
    Output Analog, Pulse
    Configuration Non-explosionproof, IP65 (Install under the eaves)
    Body material FC250 Stainless steel
    Applicable fluids Kerosene oil, light oil, heavy oil water

    *: 2 to 5 mPa·s in viscosity

  • OVAL FLOW METER MECHANICAL COUNTER

    OVAL FLOW METER MECHANICAL

     

    Major Specifications
    Model Single case type Double case (inner and outer cases) type
    Nominal size 80 to 200mm 250 to 300mm 25mm 40, 50mm 50 to 200mm
    Transmission system 7 4 2 4
    Connection standard (Flange) JIS 10,20K JIS 10,16,20,30K JIS 30K JIS 10,16,20,30,40,63K
    ASME/JPI 150 ASME/JPI 150,300 ASME 300 ASME/JPI 150,300,600
    Flow range* 4 to 450m3/h
    (5types)
    30 to 1000m3/h
    (2types)
    0.08 to 4m3/h
    (2types)
    0.26 to 40m3/h
    (3types)
    2 to 450m3/h
    (6types)
    Operating temp. range -10 to +120°C -5 to +120°C -5 to +120°C
    or
    +120 to +200°C
    -5 to +120°C
    Max. operating pressure 1.96MPa
    (Depends on connection standard.)
    4.59MPa
    (Depends on connection standard.)
    4.51MPa
    (120°C Max.)
    9.51MPa
    (Depends on connection standard.)
    Accuracy Within ±0.5% or ±0.2% of reading
    Power supply Not necessary (Power supply is required for output available model.)
    Output Pulse (Option)
    Configuration Explosionproof and also output type is available.
    Applicable fluids Water, gasoline, light oil, heavy oil, etc.

    *:5 to 1000 mPa·s in viscosity

    Major Specifications (With jacket)
    Model Jacketed single case type
    Nominal size 25,40,50mm 100,150,200mm
    Transmission system 7
    Connection standard (Flange) JIS 10K, ASME 150
    Flow range* 0.15 to 38m3/h
    (5types)
    30 to 1000m3/h
    (2types)
    Operating temp. range -5 to +120°C or +120 to +200°C
    Max. operating pressure 1.18MPa (220°C Max.)
    Accuracy Within ±0.5% of reading
    Power supply Not necessary (Power supply is required for output furnished model.)
    Output Pulse (Option)
    Configuration Explosionproof and also output type is available.
    Applicable fluids Water, gasoline, light oil, heavy oil, etc.

     

  • Oval Flow Meter Vortex EX Delta II Battery Powered PAF5

    OVAL FLOW METER VORTEX EX DELTA II Battery Powered PAF5 Model

     

    GENERAL SPECIFICATIONS
    Model Standard Dia-shaped
    Nominal
    size
    Wafer type 10 to 150mm(15 mm min. for steam) 15 to 80mm
    Flange type 15 to 300mm 50, 80mm
    Applicable tube size
    Flow
    range
    Fluid (water) 0.2* to 2510m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    0.8 to 172m3/h(5 types)
    Gas (0.2 MPa air) 2*to 15000m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    Steam (0.5 MPa
    saturated steam)
    0.02 to 47.6t/h (10 types)
    (15mm min.)
    Applicable fluid Liquid, gas, steam Liquid
    Operating temp. range –30 to +300°C
    –30 to +460°C(For high temperature of replaceable sensor)
    Flange standard JIS 10, 20, 30K ASME/JPI 150, 300, 600
    Max. operating pressure 4.51MPa (Depends on flange standard and flange material.)
    Accuracy ±1% of reading or ±1% of full scale
    Power supply DC-powered or battery-powered
    Body material SUS316 or SCS14A
    Configuration Explosionproof or non-explosionproof,
    IP66 (DC-powered), IP65 (battery-powered))
    Output Analog, pulse
  • Oval Flow Meter Vortex EX Delta II Smart Model

    OVAL FLOW METER VORTEX EX DELTA II SMART MODEL

     

    GENERAL SPECIFICATIONS
    Model Standard Dia-shaped
    Nominal
    size
    Wafer type 10 to 150mm(15 mm min. for steam) 15 to 80mm
    Flange type 15 to 300mm 50, 80mm
    Applicable tube size
    Flow
    range
    Fluid (water) 0.2* to 2510m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    0.8 to 172m3/h(5 types)
    Gas (0.2 MPa air) 2*to 15000m3/h(11 types)
    (* Accuracy ±2% FS at 10 mm)
    Steam (0.5 MPa
    saturated steam)
    0.02 to 47.6t/h (10 types)
    (15mm min.)
    Applicable fluid Liquid, gas, steam Liquid
    Operating temp. range –30 to +300°C
    –30 to +460°C(For high temperature of replaceable sensor)
    Flange standard JIS 10, 20, 30K ASME/JPI 150, 300, 600
    Max. operating pressure 4.51MPa (Depends on flange standard and flange material.)
    Accuracy ±1% of reading or ±1% of full scale
    Power supply DC-powered or battery-powered
    Body material SUS316 or SCS14A
    Configuration Explosionproof or non-explosionproof,
    IP66 (DC-powered), IP65 (battery-powered))
    Output Analog, pulse
  • Oval Flowmeter EX Turbine | Oval Flow Meters

    OVAL FLOWMETER EX TURBINE

     

    Major specifications
    Model Standard type, low viscosity type Standard type, high viscosity type
    Nominal size 15~50mm 80~400mm
    Connection JIS 10, 16, 20, 30K Flange, ASME/JPI 150, 300 Flange
    Flow range 0.63~54m3/h(standard type, 5 types) 10~4500m3/h(standard type, 8 types)
    Operating temp. range -30~+120℃(standard, for non-explosionproof type)
    Operating temp. range 4.51 MPa (depends on connection standard and operating temperature)
    Accuracy ±0.2% or ±0.5% of reading
    Power supply DC-powered
    Body material SUS304, other
    Output Analog or pulse
    Configuration Explosionproof or non-explosionproof, IP66
    Applicable fluids Petroleum, liquefied gas, water, other

    *: Flowmeters for high temperature of 350°C max. and for low temperature of -196°C min. are available.

  • Oval Flowmeter ME Meter

    OVAL FLOWMETER ME METER

     

    Major specifications
    Model For cold water For hot water
    Nominal Diameter 40 to 300mm (10 types) 40 to 300mm (10 types)
    Connection JIS 10K Flange, ASME 150 Flange
    Flow range 0.7 to 2000m3/h (10 types) 1.8 to 1200m3/h (10 types)
    Operating temp. range 0 to 50°C 0 to 130°C
    Max. operating pressure 1MPa
    Accuracy ±2% or ±5% of reading
    Power supply Not necessary (Power supply is required for output available model)
    Body material SUS304, other
    Output Pulse
    Configuration Output available model is non-explosionproof type only
    Applicable fluids Water
  • Oval Flowmeter Mini Meter & New Mini Meter | Oval Gear

    OVAL FLOWMETER MINI METER & NEW MINI METER

     

    GENERAL SPECIFICATIONS MINI METER
    Model Mini Meter (with built-in instrumental error adjuster)
    Connection JIS 5K Flange ASME 150 Flange
    Flow range Light oil: 20 to 800 L/h, Heavy oil: 10 to 800 L/h
    Max. operating temp. 100°C
    Max. operating pressure 0.69MPa 1.04MPa
    Accuracy Within ±0.5% of reading
    Power supply Not necessary
    Body material FC250, FCD450
    Output None (with dedicated indicator)
    Configuration Non-explosionproof
    Applicable fluids Light oil, heavy oil, etc.

     

    GENERAL SPECIFICATIONS NEW MINI METER
    Model New Mini Meter (without instrumental error adjuster)
    Connection JIS 5K Flange
    Flow range Light oil: 20 to 800 L/h, Heavy oil: 10 to 800 L/h
    Max. operating temp. 100°C
    Max. operating pressure 0.69MPa
    Accuracy Within ±0.5% of reading
    Power supply Not necessary
    Body material FC250
    Output None
    Configuration Non-explosionproof
    Applicable fluids Light oil, heavy oil, etc.

     

  • OVAL FLOWMETER UF-II

    OVAL FLOWMETER UF-Ⅱ

     

    Major specifications
    Model Mechanical Counter
    Nominal size 80,100mm 100 to 450mm
    Connection
    standard
    (Flange)
    JIS 10K JIS 20K
    ASME 125,
    ASME/JPI 150
    ASME/JPI 150
    Flow range* 8 to 180m3/h
    (2types)
    17 to 2800m3/h
    (7types)
    Operating
    temp. range
    –5 to +120°C
    or 0 to +120°C
    –5 to +120°C
    Max.
    operating
    pressure
    0.98MPa 1.96MPa
    (Depends on
    connection standard)
    Accuracy Within ±0.2%
    of reading
    Within ±0.5% or
    ±0.2% of reading
    Power supply Not necessary (Power supply is required
    for output available model.)
    Output Pulse (Option)
    Configuration Explosionproof and also output type is available.
    Body material FC250 or SCPH2
    Applicable
    fluids
    Water, gasoline, light oil, heavy oil, etc.

    * 5 to 1000 mPa·s in viscosity

  • OVAL FLOWMETER ULTRA UF-II

    OVAL FLOWMETER ULTRA UF-II

     

    Major specifications
    Model Electronic Counter (Ultra Counter)
    Nominal size 80 to 100mm 100 to 450mm
    Connection
    standard
    (Flange)
    JIS 10K JIS 20K
    ASME 125, ASME/JPI 150 ASME/JPI 150
    Flow range* 8 to 180m3/h (2types) 17 to 2800m3/h (7types)
    Operating temp. range –5 to +120°C or 0 to +120°C –5 to +120°C
    Max. operating
    pressure
    1.37MPa (Depends on body material) 1.96MPa (Depends on connection standard)
    Accuracy Within ±0.2% of reading Within ±0.5% or ±0.2% of reading
    Power supply DC-powered or battery-powered
    Output Analog, pulse
    Configuration Explosionproof or non-explosionproof, IP66
    Body material FC250 or SCPH2
    Applicable fluids Water, gasoline, light oil, heavy oil, etc.他

    * 5 to 1000 mPa·s in viscosity

  • OVAL FLOWMETER ULTRASONIC PSONIC-L4

    OVAL FLOWMETER ULTRASONIC – PSONIC-L4

     

    Major specifications
    Applicable fluids Oil, heavy oil, other liquids (Homogeneous liquid through which an ultrasonic wave propagates)
    Nominal size 100, 150, 200, 250, 300mm
    Number of lines measured 4
    Flange standard JIS 10, 20, 30K RF / JPI 150, 300 RF / ASME 150, 300 RF
    Flow velocity measuring range −10 to +10m/s
    Accuracy ±0.5%RD (Standard), ±0.15%RD (high accuracy calibration)
    Temp. range −20 to +120°C
    Max. operating pressure Depends on flange rating (Design pressure : 8MPa at 120°C)
    Configuration Explosionproof (TIIS, ATEX), IP66
  • Oval Flowmeter Ultrasonic PSONIC-S1 | Oval Flow Meters

    OVAL FLOWMETER ULTRASONIC – PSONIC-S1

     

    Major specifications
    Applicable fluids Homogeneous fluids where ultrasonic wave can propagate (clean water, waste water, industrial water, river water, ocean water, purified water, etc.)
    Turbidity: 10000mg/L (degree) max.※1
    Fluid temp. range -20 to 60°C (fluid and ambient)
    Nominal size 25mm to 600mm
    Piping materials Steel pipe, SUS pipe, polyvinyl pipe, ductile cast-iron pipe, copper pipe, or other pipe made of material that can transmit ultrasonic wave steadily※2,3
    Flow metering range 0 to ±10m/s
    Number of metering lines 1 line
    Metering system Ultrasonic pulse transmission time difference system
    Factory calibration accuracy※4,5 25mm to 40mm ±2.5% of reading (±0.025m/s at a flowrate less than 1m/s)
    50mm to 90mm ±2.0% of reading (±0.020m/s at a flowrate less than 1m/s)
    100mm to 250mm ±1.5% of reading (±0.015m/s at a flowrate less than 1m/s)
    300mm to 600mm ±1.0% of reading (±0.010m/s at a flowrate less than 1m/s)

    ※1:The fluid must not contain bubble.

    ※2:Maximum applicable bore size may not satis by the requirement depending on the material or status of piping.

    ※3:In case of lining pipes, the lining must contact with the main pipe.(Lining material is tar epoxy or mortar, or the like.)

    ※4:Specification when measures volume flow.

    ※5:The pipe must be full of liquid and the flowrate distribution must be ideal.

  • POWOGAZ JS SMART+ COLD WATER METERS (DN15-20)

     

    Specifications :