Major specifications ( LGL, LGW )
Model |
For oil (LGL) |
For water (LGW) |
Nominal size |
20, 25, 40, 50mm |
Connection |
JIS 10K Flange
ASME 150 Flange |
JIS 10K Flange |
Flow range |
7 to 24000L/h (6 types) |
200 to 12000L/h (4 types) |
Operating temp.
range |
0 to 120°C |
0 to 80°C |
Max. operating pressure |
1.19MPa |
Accuracy |
Within ±0.5% of reading |
Within ±1% of reading |
Power supply |
DC-powered or battery-powered |
Output |
Pulse |
Configuration |
Explosionproof or non-explosionproof, IP66 |
Body material |
FC250 |
SCS13 or equivalent |
Applicable fluids |
Kerosene, light oil, heavy oil, etc. |
Water |
-
GENERAL SPECIFICATIONS
Model |
For oil |
For water |
Standard |
For high temperature |
Nominal size |
20、25、40、50mm |
20、25、40mm |
20、25、40、50mm |
Connection |
JIS 10K Flange, ASME 150 Flange |
JIS 10K Flange |
Flow range |
7 to 24000L/h (6 types) |
14 to 6400L/h (4 types) |
200 to 12000L/h (4 types) |
Operating temp. range |
0 to 120°C |
0 to 150°C |
0 to 120 °C |
Max. operating pressure |
1.18MPa |
0.98MPa |
1.18MPa(Still and flowing water) |
Accuracy |
Within ±0.5% of reading |
Within ±1% of reading |
Power supply |
DC-powered or battery-powered |
Output |
Analog, Pulse |
Configuration |
Non-explosionproof, IP65 (Install under the eaves) |
Body material |
FC250 |
Stainless steel |
Applicable fluids |
Kerosene oil, light oil, heavy oil |
water |
-
Major Specifications
Model |
Single case type |
Double case (inner and outer cases) type |
Nominal size |
80 to 200mm |
250 to 300mm |
25mm |
40, 50mm |
50 to 200mm |
Transmission system |
7 |
4 |
2 |
4 |
Connection standard (Flange) |
JIS 10,20K |
JIS 10,16,20,30K |
JIS 30K |
JIS 10,16,20,30,40,63K |
ASME/JPI 150 |
ASME/JPI 150,300 |
ASME 300 |
ASME/JPI 150,300,600 |
Flow range |
4 to 450m3/h
(5types) |
30 to 1000m3/h
(2types) |
0.08 to 4m3/h
(2types) |
0.26 to 40m3/h
(3types) |
2 to 450m3/h
(6types) |
Operating temp. range |
-10 to +120°C |
-5 to +120°C |
-5 to +120°C
or
+120 to +200°C |
-5 to +120°C |
Max. operating pressure |
1.96MPa
(Depends on connection standard.) |
4.59MPa
(Depends on connection standard.) |
4.51MPa
(120°C Max.) |
9.51MPa
(Depends on connection standard.) |
Accuracy |
Within ±0.5% or ±0.2% of reading |
Power supply |
Not necessary (Power supply is required for output available model.) |
Output |
Pulse (Option) |
Configuration |
Explosionproof and also output type is available. |
Applicable fluids |
Water, gasoline, light oil, heavy oil, etc. |
Major Specifications (With jacket)
Model |
Jacketed single case type |
Nominal size |
25,40,50mm |
100,150,200mm |
Transmission system |
7 |
Connection standard (Flange) |
JIS 10K, ASME 150 |
Flow range |
0.15 to 38m3/h
(5types) |
30 to 1000m3/h
(2types) |
Operating temp. range |
-5 to +120°C or +120 to +200°C |
Max. operating pressure |
1.18MPa (220°C Max.) |
Accuracy |
Within ±0.5% of reading |
Power supply |
Not necessary (Power supply is required for output furnished model.) |
Output |
Pulse (Option) |
Configuration |
Explosionproof and also output type is available. |
Applicable fluids |
Water, gasoline, light oil, heavy oil, etc. |
-
GENERAL SPECIFICATIONS MINI METER
Model |
Mini Meter (with built-in instrumental error adjuster) |
Connection |
JIS 5K Flange |
ASME 150 Flange |
Flow range |
Light oil: 20 to 800 L/h, Heavy oil: 10 to 800 L/h |
Max. operating temp. |
100°C |
Max. operating pressure |
0.69MPa |
1.04MPa |
Accuracy |
Within ±0.5% of reading |
Power supply |
Not necessary |
Body material |
FC250, FCD450 |
Output |
None (with dedicated indicator) |
Configuration |
Non-explosionproof |
Applicable fluids |
Light oil, heavy oil, etc. |
-
Major specifications
Model |
Mechanical Counter |
Nominal size |
80,100mm |
100 to 450mm |
Connection
standard
(Flange) |
JIS 10K |
JIS 20K |
ASME 125,
ASME/JPI 150 |
ASME/JPI 150 |
Flow range |
8 to 180m3/h
(2types) |
17 to 2800m3/h
(7types) |
Operating
temp. range |
–5 to +120°C
or 0 to +120°C |
–5 to +120°C |
Max.
operating
pressure |
0.98MPa |
1.96MPa
(Depends on
connection standard) |
Accuracy |
Within ±0.2%
of reading |
Within ±0.5% or
±0.2% of reading |
Power supply |
Not necessary (Power supply is required
for output available model.) |
Output |
Pulse (Option) |
Configuration |
Explosionproof and also output type is available. |
Body material |
FC250 or SCPH2 |
Applicable
fluids |
Water, gasoline, light oil, heavy oil, etc. |
-
Major specifications
Model |
Electronic Counter (Ultra Counter) |
Nominal size |
80 to 100mm |
100 to 450mm |
Connection
standard
(Flange) |
JIS 10K |
JIS 20K |
ASME 125, ASME/JPI 150 |
ASME/JPI 150 |
Flow range |
8 to 180m3/h (2types) |
17 to 2800m3/h (7types) |
Operating temp. range |
–5 to +120°C or 0 to +120°C |
–5 to +120°C |
Max. operating
pressure |
1.37MPa (Depends on body material) |
1.96MPa (Depends on connection standard) |
Accuracy |
Within ±0.2% of reading |
Within ±0.5% or ±0.2% of reading |
Power supply |
DC-powered or battery-powered |
Output |
Analog, pulse |
Configuration |
Explosionproof or non-explosionproof, IP66 |
Body material |
FC250 or SCPH2 |
Applicable fluids |
Water, gasoline, light oil, heavy oil, etc.他 |
-
GENERAL SPECIFICATIONS
Basic Meter
Meter Size |
39 |
41 |
45 |
50 |
52 |
53 |
Nominal Size |
10mm |
20mm |
25mm |
Flange Rating |
Group 1 |
JIS10KRF, ASME/JPI150RF |
Group 3 |
JIS16, 20, 30KRF, ASME/JPI300RF, DIN10, 16, 20, 25 |
Flowrange |
2頁参照 |
Operating Temp. Range |
–10 to +120˚C |
Linearity |
±0.35% |
±0.35% or ±0.15% |
Repeatability |
±0.35% |
±0.05% or ±0.02% |
Material |
Meter Body |
SUS316L |
SCS14 (or SUS316), SCS16 (or SUS316L) |
Cover |
SUS316L |
SUS316 or SUS316L |
Rotor |
Special Carbon |
SCS14 (or SUS316), SCS16 (or SUS316L) |
Bearings |
Special Carbon |
Special Carbon or Ceramics |
Shaft |
SUS316L |
SUS316 or SUS316L |
Flow direction |
Right → Left (St’d) Left → Right Top → Bottom Bottom → Top |
Finish |
Body, Rear Cover:No coating Skirt:Finished |
-
Major specifications
Model |
Standard |
High temp. |
Low temp. |
Nominal size |
10 to 50mm |
20 to 50mm |
Connection |
JIS 10, 16, 20, 30K flange, ASME/JPI 150, 300 flange |
Flow range |
0.2L/h to 44m3/h(9 types) |
0.05 to 44m3/h (6 types) |
0.03 to 44m3/h(6 types) |
Operating temp. range |
–10 to +120°C |
120 to 260°C |
–60 to +60°C |
Max. operating pressure |
2.94MPa (depends on connection standard.) |
Linearity |
±0.35% or ±0.15% |
Power supply |
DC-powered or battery-powered |
Body material |
SCS14 |
Output |
Analog, pulse |
Configuration |
Explosionproof or non-explosionproof, IP66 |
Applicable fluids |
Water, gasoline, light oil, heavy oil, etc. |
General specifications for nominal size 80 mm and bigger
Nominal size |
80 to 350mm |
Flow range |
4 to 1000m3/h (8types) |
Linearity |
±0.35% or ±0.15% |